Quantcast
Channel: Fortinet GURU
Viewing all articles
Browse latest Browse all 2380

FortiSIEM VM Network IO Monitoring

$
0
0

VM Network IO Monitoring

Event Type: PH_DEV_MON_VM_STATE

Description: Event containing VM CPU metrics Source: All

Key Attributes:

Name Id Type Description
Event Type eventType string Event type set to PH_DEV_MON_SYS_PING_STAT
Event

Severity

eventSeverity uint16 Set to 1. In general, a number between 0 (lowest severity) and 10 (highest severity)
Event

Severity

Category

eventSeverityCat string Set to Low. IN general, takes the values Low, Medium and High. Event Severities 0-4 are mapped to Low, 5-8 are mapped to Medium and 9-10 are mapped to High
Event

Receive

Time

phRecvTime Date Time at which AccelOps generated this event
Reporting IP reptDevIpAddr Date IP address of device reporting this event. In this case set to the device reporting the utilization (same as

Host name attribute)

Relaying IP relayDevIpAddr Date IP address of device relaying this event from the source to AccelOps. In general it could be a syslog-ng IP address but in this, since AccelOps talks to the device directly, Relaying IP is set to AccelOps IP Address.
Raw Event

Log

rawEventMsg string Raw event containing all attributes in comma separated “[Attribute] = value” format.
vmName
Host name hostName string Host name (as in AccelOps CMDB) of the device whose CPU utilization is being reported
Host IP

Address

hostIpAddr IP Access IP (as in AccelOps CMDB) of the device whose CPU utilization is being reported
phyMachName string
phyMachIpAddr IP
vSwitch string
intfName string
sentPkts uint32 Sent Packets
recvPkts uint32 Received Packets
sentBytes uint32 Sent Bytes
recvBytes uint32 Received Bytes
Poll Interval pollIntv uint32 Polling interval in seconds

Sample event:

<134>Feb 08 18:22:16 10.1.2.11 java:

[PH_DEV_MON_VM_NET_INTF_UTIL]:[eventSeverity]=PHL_INFO,[phyMachName

]=HOST-10.1.2.51,

[phyMachIpAddr]=10.1.2.51, [pollIntv]=180, [vmName]=CO159,

[morId]=vm-194, [hostName]=CO159, [hostIpAddr]=10.1.2.159,

[vSwitch]=vSwitch0, [intfName]=Network adapter 1, [sentPkts]=454,

[recvPkts]=939, [sentBytes]=102400, [recvBytes]=307200

VM Cluster CPU Utilization

VM Cluster Memory Utilization

VM Cluster Datastore I/O Utilization

VM Resource pool CPU Utilization

 

VM Resource pool Memory Utilization

ESX State Monitoring

ESX Datastore Utilization Monitoring

ESX Disk I/O Monitoring

<134>Oct 02 12:00:42 192.168.1.3 java:

[PH_DEV_MON_ESX_DISK_IO]:[eventSeverity]=PHL_INFO,

[hostName]=ESX3i-QA-01.prospecthills.net, [hostIpAddr]=192.168.1.3,

[pollIntv]=180, [morId]=ha-host, [diskName]=mpx.vmhba32:C0:T0:L0,

[diskReadKBytesPerSec]=9.9, [diskWriteKBytesPerSec]=0.3,

[diskReadReqPerSec]=1.215, [diskWriteReqPerSec]=0.045,

[devDiskRdLatency]=0.1, [devDiskWrLatency]=0.4, [kernDiskRdLatency]=0.0,

[totDiskRdLatency]=0.1, [totDiskWrLatency]=0.4, [kernDiskWrLatency]=0.0