FortiGate–3000D fast path architecture
The FortiGate-3000D features 16 front panel SFP+ 10Gb interfaces connected to two NP6 processors through an
Integrated Switch Fabirc (ISF). The FortiGate-3000D has the following fastpath architecture:
l 8 SFP+ 10Gb interfaces, port1 through port8 share connections to the first NP6 processor (np6_0).
l 8 SFP+ 10Gb interfaces, port9 through port16 share connections to the second NP6 processor (np6_1).
CONSOLE
MGMT 1
1 3 5
SFP+
7 9
11 13 15
STATUS ALARM HA
POWER
USB
MGMT 2
2 4 6
8 10 12
14 16
Integrated Switch Fabric
FortiASIC NP6
FortiASIC NP6
|
System Bus
CP8
CPU
CP8
CP8 CP8
You can use the following get command to display the FortiGate-3000D NP6 configuration. The command output shows two NP6s named NP6_0 and NP6_1 and the interfaces (ports) connected to each NP6. You can also use the diagnose npu np6 port-list command to display this information.
get hardware npu np6 port-list
Chip XAUI Ports Max Cross-chip
Speed offloading
—— —- ——- —– ———- np6_0 0 port1 10G Yes
0 port6 10G Yes
1 port2 10G Yes
1 port5 10G Yes
2 port3 10G Yes
2 port8 10G Yes
3 port4 10G Yes
3 port7 10G Yes
—— —- ——- —– ———- np6_1 0 port10 10G Yes
0 port13 10G Yes
1 port9 10G Yes
1 port14 10G Yes
2 port12 10G Yes
2 port15 10G Yes
3 port11 10G Yes
3 port16 10G Yes
—— —- ——- —– ———-